Service Entrance - Surge Protectors - NEMA Enclosures  |
| Service Entrance - Din Rail SPD |
MDS750E,
MDS600E,
MDS300E
(Enhanced)
 |
NEW UL1449 ed4 Type 1 SPD!
Characteristics,
- Surge Capacity to 750kA 8/20us per phase
- Lightning Capacity to 15kA 10/350us per phase
- UL1449 Nominal
Discharge Current (In) 20kA (All models)
- UL1449 Short-circuit Current Rating (SCCR) 200kA (All models)
- UL96A Master Label Compliant
- Surge Rated Disconnect Switch
- Enhanced Diagnostics - % of protection present, surge counter, audible, remote, test/mute
- Replaceable Modular Design for SPD and Filter (if applicable)
- Optional Listing as Type 2 Listed with UL1283 and cUL
- NEMA 4/12 (Stainless Steel NEMA 4X optional)
*Available in 750kA, 600kA, 300kA
**Models MDS750E, MDS600E, MDS300E
UL1449 4th Edition - Type 1 Listed, Surge Protective Device
Data Sheet |
| |
MDS750S, MDS600S,
MDS300S
(Standard)
 |
NEW UL1449 ed4 Type 1 SPD!
Characteristics,
- Surge Capacity to 600kA 8/20us per phase
- Lightning Capacity to 15kA 10/350us per phase
- UL1449 Nominal
Discharge Current (In) 20kA (All models)
- UL1449 Short-circuit Current Rating (SCCR) 200kA (All models)
- UL96A Master Label Compliant
- Internal Surge Rated Fusing
- Standard Diagnostics - % of protection present, audible, remote, test/mute
- Replaceable Modular Design for SPD and Filter (if applicable)
- Optional Listing as Type 2 Listed with UL1283 and cUL
- NEMA 4/12 (Stainless Steel NEMA 4X optional)
*Available in 750kA, 600kA, 300kA
**Models MDS750S, MDS600S, MDS300S
UL1449 4th Edition - Type 1 Listed, Surge Protective Device
Data Sheet |
| |
MDS750,
MDS600,
MDS300
(Basic)
 |
NEW UL1449 ed4 Type 1 SPD!
Characteristics,
- Surge Capacity to 300kA 8/20us per phase
- Lightning Capacity to 15kA 10/350us per phase
- UL1449 Nominal
Discharge Current (In) 20kA (All models)
- UL1449 Short-circuit Current Rating (SCCR) 200kA (All models)
- UL96A Master Label Compliant
- Standard Diagnostics - % of protection present, audible, remote, test/mute
- Replaceable Modular Design for SPD and Filter (if applicable)
- Optional Listing as Type 2 Listed with UL1283 and cUL
- NEMA 4/12 (Stainless Steel NEMA 4X optional)
*Available in 750kA, 600kA, 300kA
**Models MDS750, MDS600, MDS300
UL1449 4th Edition - Type 1 Listed, Surge Protective Device
Data Sheet |
| |
M200

|
CITEL model M200 Series is a high performance surge protector designed for critical panel locations. The SPD incorporates high-energy MOVs with EMI/RFI noise filtering to provide protection against transients originating from induced lightning strikes and utility switching.
UL1449 3rd Edition
Data Sheet |
| |
M160

|
CITEL model M200 Series is a high performance surge protector designed for critical panel locations. The SPD incorporates high-energy MOVs with EMI/RFI noise filtering to provide protection against transients originating from induced lightning strikes and utility switching.
UL1449 3rd Edition
Data Sheet |
| |
M50

|
NEW UL1449 ed4 Type 1 SPD!
Characteristics,
- Surge Capacity to 50kA 8/20us per mode, 100kA 8/20us Total
- UL1449 Nominal
Discharge Current (In) 20kA (All models)
- UL1449 Short-circuit Current Rating (SCCR) 200kA (All models)
- UL96A Master Label Compliant
- Hybrid TOV circuit provides immunity during high line conditions
- No leakage current design increases life expectancy of SPD, no GFI tripping
- Visual LED fault indicator and audible alarm
- NEMA 6 (exceeds NEMA 4X or 4)
- Optional Type 2 Listed with UL1283 Filter, Model M50F Series (Data Sheet)
UL1449 4th Edition - Type 1 Listed, Surge Protective Device
Data Sheet |
| |
M50F

|
NEW UL1449 ed4 Type 2 SPD!
Characteristics,
- Surge Capacity to 50kA 8/20us per mode, 100kA 8/20us Total
- UL1449 Nominal
Discharge Current (In) 20kA (All models)
- UL1449 Short-circuit Current Rating (SCCR) 200kA (All models)
- UL96A Master Label Compliant (use M50 Type 1 SPD Series)
- UL1283 Listed Filter
- Hybrid TOV circuit provides immunity during high line conditions
- No leakage current design increases life expectancy of SPD, no GFI tripping
- Visual LED fault indicator and audible alarm
- NEMA 6 (exceeds NEMA 4X or 4)
- Optional Type 1 Listed, Model M50 Series (Data Sheet)
UL1449 4th Edition - Type 2 Listed, Surge Protective Device
Data Sheet |
|
|
| |
CITEL INC. 10108 USA Today Way | Miramar, FL 33025 USA | Toll Free 800.248.3548 | Tel: 954.430.6310| Fax 954.430.7785
|